Snow load, frost line and wind: building for northern New Hampshire's climate

Northern NH ground snow loads run 75 to 105+ psf, so most North Country roofs need engineering. The frost line is 48 to 60 inches. Town values inside.

By Fregeau Builders, Littleton NH · Updated · 14 min read

Red barn-style Jackson Public Library with a standing-seam metal roof, surrounded by deep snow banks
Jackson Public Library in winter. The state's snow load study lists Jackson at 115 psf at 1,800 feet. Photo: Paul Klenk, CC BY 3.0, via Wikimedia Commons.

In northern New Hampshire, a house has to be designed for ground snow loads of roughly 75 to 105 pounds per square foot or more, a frost line (minimum footing depth) of 48 to 60 inches, and climate zone 6 insulation levels. The Army Corps of Engineers’ New Hampshire snow load study lists 75 psf for Littleton at 1,200 feet and 105 psf for Bethlehem at 1,800 feet. Both are above the 70 psf limit where the 2024 IRC’s prescriptive framing rules stop, so most North Country roofs need an engineered design. The frost line is set by each town; Bethlehem’s permit form requires 60 inches.

Jump to the town table to find the reference elevation for your town. The table gives ground loads. Ask your designer which values apply to your particular site and roof.

What is the ground snow load in northern New Hampshire?

In 2002 the US Army Corps of Engineers’ Cold Regions Research and Engineering Laboratory (CRREL) in Hanover ran snow load case studies for all 259 New Hampshire towns. The result, report ERDC/CRREL TR-02-6, gives each town one value at one elevation. Towns have used it for years to fill in the ground snow load on their code tables.

Town values for the Littleton area

TownGround snow load (psf)At elevation (ft)
Littleton751,200
Bethlehem1051,800
Franconia951,700
Sugar Hill901,600
Lisbon751,100
Lincoln951,400
Easton851,400
Whitefield801,400
Landaff801,300
Monroe651,000
Jefferson1001,700
Waterville Valley1051,800
Jackson1151,800

Source: CRREL TR-02-6, Table 1. For comparison, the same table gives Concord 70 psf and Portsmouth 50 psf.

Adjusting for your site’s elevation

The table value “only applies at the elevation listed.” The report’s rule is to add 2.1 psf for every 100 feet above that elevation, or subtract 2.1 psf for every 100 feet below, and to round to the nearest 5 psf. Some worked examples:

SiteMathResult
Littleton lot at 1,600 ft75 + 2.1 × 4 = 83.4about 85 psf
Bethlehem lot at 1,400 ft105 − 2.1 × 4 = 96.6about 95 psf
Sugar Hill lot at 1,900 ft90 + 2.1 × 3 = 96.3about 95 psf
Lisbon lot at 800 ft75 − 2.1 × 3 = 68.7about 70 psf

Above 2,500 feet the report says not to use the table at all: “Conduct a site-specific snow load case study.” Very few house lots are that high, but some ridgeline and ski-area parcels come close. Bethlehem prints its own figure, “Snow load 105 at 1800’ elevation,” right on its new single-family permit application.

Did the 2024 code change how snow loads are set?

For houses, no; for engineered buildings, yes. New Hampshire moved to the 2024 IRC and IBC on July 1, 2026, with a concurrency period to December 31, 2026 (NH Division of Fire Safety). Our permits guide covers those dates.

The official 2024 IRC with New Hampshire amendments, which governs houses, still says the jurisdiction “shall fill in” the ground snow load on Table R301.2 using Table 1 of CRREL TR-02-6 (ICC, 2024 IRC with NH amendments, Chapter 3). The town values above still apply.

For engineered design, the Structural Engineers of New Hampshire note that the 2024 IBC references ASCE 7-22, which uses new “reliability-targeted” ground snow loads, and that the CRREL case studies no longer apply to that method. Engineers pull those values from the ASCE Hazard Tool.

In practice, house roofs in the North Country end up engineered anyway (see the next section), and the engineer picks the method. Ask which one they used and what ground load came out of it. If an ASCE 7-22 number is much lower than the CRREL figure your town prints on its form, talk it through with the building official before framing is ordered.

What does a high snow load mean for roof design?

The 70 psf line

IRC section R301.2.3 lets wood-framed houses use the code’s prescriptive chapters only where the allowable-stress ground snow load is 70 psf or less. Above 70 psf, the building “shall be designed in accordance with accepted engineering practice.” Look at the table above: every town listed except Monroe is over 70 at its reference elevation.

In practice:

  • Trusses come from the manufacturer with sealed engineering for the load you specify. Give them the site-adjusted load, not a generic number.
  • Rafters, ridge beams, headers and girders can’t come straight from the IRC span tables. They need sizing by an engineer or from a manufacturer’s engineered product tables at the right load.
  • Timber frames are engineered as a matter of course; the design snow load drives timber sizes and joinery. Our timber frame vs. stick-built comparison goes into that.
  • Decks and porch roofs carry snow too, and snow sliding off a main roof can pile onto them.

Ground load is only the starting point

The roof load an engineer designs for depends on more than the ground figure. FEMA guidance summarized by the Building America Solution Center lists the factors: roof shape, snow type, repeated storms, ice, snow sliding from a roof above, and how warm the space under the roof is.

Valleys, dormers, parapets and the step down to a lower roof are “aerodynamically shaded” and collect drifts that can be “significantly higher than the ground snow load.”

Sliding snow is the other concern. Roofs under about 30 degrees (a 5:12 to 6:12 pitch) generally won’t shed significant snow. Steeper metal roofs will, and the falling snow can overload a lower roof. Don’t put an entry door, a walkway, or a heat pump’s outdoor unit under a steep metal eave without snow guards or a plan.

The weight also varies with the snow: a foot of light, dry snow weighs about 3 psf and a foot of heavy, wet snow about 21 psf; an inch of ice weighs about 5 psf (FEMA P-957 via BASC). Rain on an existing snowpack makes it heavier still.

Simple roof shapes are cheaper to build and carry snow more predictably. Every valley, dormer and roof-to-wall intersection adds a drift zone and an ice dam risk.

What is the frost line in New Hampshire, and how deep do footings go?

There is no single state number. The IRC tells “the jurisdiction” to fill in the frost line depth on Table R301.2 as “the minimum depth of footing below finish grade” (UpCodes, NH IRC 2024). Towns publish their own:

TownFrost line depthSource
Bethlehem60 inchesPermit application
Lebanon4 ft for heated buildings; unheated may need moreCity code §36-11
Alton48 inchesCodes & Design Criteria
Francestown48 inchesPermit guide
Amherst48 inches minimumDesign criteria

Four feet is the common figure statewide. Bethlehem’s 60 inches shows that a North Country town can and does set more. Littleton, Franconia and Sugar Hill don’t have building departments that publish a design table we could find, so ask your engineer to state the frost depth on the foundation drawings. Lebanon’s note also matters: an unheated garage, barn or porch footing doesn’t get any warmth from the house and may need more depth or insulation.

Most new houses in this area go on a full basement, which puts the footings well below frost anyway. Frost depth bites on garages, porches, additions, deck piers and slab-on-grade designs. Ledge is the other wild card: hitting rock at three feet changes the foundation plan and the budget. We cover that in site costs for septic, well and ledge.

Is a frost-protected shallow foundation allowed?

Yes. A frost-protected shallow foundation (FPSF) uses rigid foam insulation around and out from the footing to keep the ground below it from freezing, so the footing can sit much higher. The simplified FPSF design method “is adopted by the model building codes,” according to the NAHB Research Center’s builder’s guide.

The design keys off the site’s air freezing index (AFI), a measure of how cold and long the winter is:

Air freezing index (°F-days)Vertical insulation R-valueHorizontal insulation along wallsMinimum footing depth
2,000R-5.6Not required14 in
2,500R-6.7R-1.716 in
3,000R-7.8R-6.516 in
3,500R-9.0R-8.016 in
4,000R-10.1R-10.516 in

Source: NAHB Research Center, simplified method for heated buildings, Table 3 (builder’s guide).

Southern NH towns publish AFI values of about 1,250 to 2,000 (for example Amherst and Alton). The North Country is colder, so get a station value from NOAA’s FPSF data rather than guessing. Limits to know:

  • The simplified method assumes a heated building and a slab insulated to less than R-10, because it relies on house heat. Attached unheated garages need the detailed method or conventional footings.
  • Below-grade foam loses some value when wet; the guide derates XPS by about 10% and EPS by about 20%.
  • The guide says drainage must carry water “over the grade and away from the foundation.”

An FPSF makes the most sense for a slab-on-grade house, an addition, or a heated garage on a site where deep digging means blasting ledge. It is not the default here, and the design should come from someone who has done it before.

What climate zone is northern New Hampshire, and what does that require?

New Hampshire’s EC-1 energy code form puts Cheshire, Hillsborough, Rockingham and Strafford counties in climate zone 5 and all other counties in zone 6, so all of Grafton and Coos is zone 6 (NH EC-1 form). The state still uses the 2018 IECC for energy, even after the July 2026 code update (NH Division of Fire Safety).

AssemblyZone 6 minimum on the EC-1 form
Attic ceilingR-49 (R-38 allowed if full depth is kept over the wall plates)
Above-grade wallR-20 cavity + R-5 continuous, or R-13 + R-10
Basement or crawl wallR-19 cavity or R-15 continuous
Slab edgeR-10 extending 4 ft (2 ft in zone 5)
WindowsU-0.30 maximum
Air leakage3 air changes per hour at 50 Pa, by blower door test

Source: NH EC-1 form, 2018 IRC Chapter 11 provisions.

These are minimums; our post on energy-efficient homes, heat pumps and rebates covers when it pays to go further.

How do you prevent ice dams on a new house?

Ice dams form when house heat warms the roof deck, snow melts, and the water refreezes at the cold eave. The Building America Solution Center notes they “can form with as little as 2 inches of snow” and lists three defenses, with air sealing first (BASC, ice dam prevention):

  1. Air seal the ceiling. Common leaks are wiring and plumbing holes, recessed lights, chimneys and flues, attic hatches, exhaust fans and top plates. John Straube of Building Science Corporation warns that adding vents without sealing leaks can make things worse by giving the warm air an easier path out (BSD-135).
  2. Insulate deeply, including over the wall plates. Raised-heel (“energy”) trusses let full-depth insulation run over the outside walls, where ice dams start. BASC recommends R-60 or more for vented attics in zones 5 and up, above the R-49 code minimum (BASC).
  3. Ventilate under the deck. Joe Lstiburek recommends a 2-inch vent space, not the 1 inch the code requires, where ground snow loads exceed 30 psf (BSI-097). Vent every rafter bay from soffit to ridge, and don’t over-vent the exhaust side.
Snow-covered slate roof with dormers and a thick band of ice and long icicles along the eave
An ice dam on a slate roof: snow melted by attic heat refreezes at the cold eave. Photo: Dmcroof, CC BY-SA 3.0, via Wikimedia Commons.

Design choices that raise the risk, per University of Minnesota Extension and BASC: recessed lights in the top-floor ceiling, skylights, complex roofs, and ducts or air handlers in the attic. For cathedral ceilings and other compact roofs where ground snow is over 60 psf, BASC recommends a vented “over-roof”: a second deck on battens above the insulated roof, so outside air flows under the roofing. In zone 6, a vented attic also needs at least a Class II vapor retarder on the warm side of the ceiling insulation.

The IRC also requires an ice barrier membrane at the eaves where the town records a history of ice damming (UpCodes, Table R301.2 note h). That membrane limits leaks if a dam forms but doesn’t stop the dam.

How much wind does a northern NH house have to handle?

Towns fill in the design wind speed from the IRC’s map, and the code says the “wind exposure category shall be determined on a site-specific basis” (UpCodes, NH IRC 2024). Published values include 100 mph in Bethlehem and 115 mph in Alton and Francestown. The code also provides for topographic speed-up on hills and ridges where there is local history of damage.

The lots people want around here, open fields with a Presidential or Franconia Ridge view, are the ones with the most wind exposure. Ask the engineer what exposure category and topographic factor they used, and make sure roof-to-wall connections, sheathing nailing and large window openings are designed for it. Wind also moves snow: an open hilltop roof may be scoured on one side and drifted on the other.

How do mud season and drainage affect building?

Spring road postings

Under RSA 231:191, towns may post seasonal weight limits on class IV, V and VI roads, and driving a heavier vehicle on them needs written permission from the selectmen or road agent. The UNH Technology Transfer Center explains why: saturated road bases lose strength during the thaw, and postings stay up until roads recover, with “no fixed calendar date.” Typical postings are 6 tons, as in New Boston in March 2026 and Gilmanton. Conway posts at 10 tons and requires a $5,000 surety per town road for overweight travel.

Loaded concrete, gravel and lumber trucks are far heavier than 6 tons. If your lot is on a posted town road, plan foundation pours and big deliveries around the posting, or get the road agent’s permission and conditions in writing ahead of time. More on scheduling around the seasons is in our post on building a house in winter.

Site drainage

Frost heave needs water. Keep the soil around the foundation drained and you take away most of the risk, which is why the NAHB FPSF guide insists on a clear path for water “away from the foundation.” On a sloped North Country lot that means footing drains to daylight, grading that falls away from the house, gutters or drip edges that discharge well clear, and a driveway that doesn’t funnel spring runoff toward the garage door.

What should you ask your builder or engineer?

  1. What ground snow load did you use, from which source (CRREL table or ASCE 7-22 Hazard Tool), and at what site elevation?
  2. What design roof snow load results, and where are the drift and sliding-snow zones on this roof?
  3. Are the trusses ordered at that load, and who sized the beams, headers and any rafters?
  4. If we pick a steep metal roof, where will the snow land, and do we need snow guards over doors, walkways or equipment?
  5. What frost depth are the footings designed to, and how are unheated areas like the garage and porch handled?
  6. If ledge is shallow, have you considered a frost-protected shallow foundation, and what air freezing index did you use?
  7. Which wind exposure category and topographic factor did you assume for this site?
  8. How is the ceiling air-sealed, how much insulation runs over the wall plates, and how big is the vent gap under the deck?
  9. Will any ducts, air handlers or recessed lights sit in or below the attic?
  10. What blower door number are you targeting, and who runs the test?
  11. Is our road posted in spring, and how does that affect the foundation and framing schedule?
  12. Where does water go: footing drains, grading, gutters and the driveway?

If you are planning a house in Littleton, Bethlehem, Franconia or nearby, these are the questions we work through with clients before a design is final, and we’re glad to go over your site. See our custom homes page or contact us.

Sources

  1. US Army Corps of Engineers, ERDC/CRREL TR-02-6: Ground Snow Loads for New Hampshire (2002) (accessed November 2026)
  2. International Code Council: 2024 International Residential Code with New Hampshire Amendments, Chapter 3 (accessed November 2026); UpCodes mirror
  3. Structural Engineers of New Hampshire: New Hampshire State Building Code (accessed November 2026)
  4. NH Division of Fire Safety: State Building Code (accessed November 2026)
  5. Town of Bethlehem: New Single-Family Construction Building Permit Application (accessed November 2026)
  6. Building America Solution Center (FEMA): Managing Snow Loads on Roofs and Decks (accessed November 2026)
  7. City of Lebanon, NH: Code §36-11, Construction Regulations (accessed November 2026)
  8. Town of Alton, NH: Codes & Design Criteria (accessed November 2026)
  9. Town of Francestown, NH: Building Permit Application Guide (accessed November 2026)
  10. Town of Amherst, NH: Climatic and Geographic Design Criteria (accessed November 2026)
  11. NAHB Research Center: Revised Builder’s Guide to Frost Protected Shallow Foundations (accessed November 2026)
  12. NOAA NCEI: Frost Protected Shallow Foundations data (accessed November 2026)
  13. NH Residential Energy Code Application (EC-1 Form), 2018 IRC Chapter 11 (accessed November 2026)
  14. Building America Solution Center: Attic Air Sealing, Insulating, and Ventilating for Ice Dam Prevention (accessed November 2026)
  15. Building America Solution Center: Construct Roofs and Attics for Ice Dam Prevention (accessed November 2026)
  16. Building Science Corporation: BSD-135 Ice Dams (John Straube) (accessed November 2026)
  17. Building Science Corporation: BSI-097 De-Icing Ice Dams (Joseph Lstiburek) (accessed November 2026)
  18. University of Minnesota Extension: Dealing with and preventing ice dams (accessed November 2026)
  19. NH RSA 231:191, Maximum Weight Limits (accessed November 2026)
  20. UNH Technology Transfer Center: Frost Heaves, Gravel Roads & Seasonal Weight Limits (2026) (accessed November 2026)
  21. Town of New Boston, NH: Public Notice, Road Weight Limit (March 9, 2026) (accessed November 2026)
  22. Town of Gilmanton, NH: Public Works / Highway (accessed November 2026)
  23. Town of Conway, NH: Spring Road Ban Travel Permit Application (rev. Nov. 20, 2024) (accessed November 2026)

Frequently asked questions

What is the snow load for a house in Littleton, NH?

The Army Corps of Engineers' Ground Snow Loads for New Hampshire lists 75 pounds per square foot at 1,200 feet for Littleton, adjusted by 2.1 psf per 100 feet of elevation. A house site at 1,600 feet would work out to about 83 psf, usually rounded to 85. That is the ground load; the engineer converts it to a roof load based on roof shape, exposure and heat loss.

How deep do footings need to be in New Hampshire?

Each town sets the frost line depth in its code table. Most published values in New Hampshire are 48 inches to the bottom of the footing, and Bethlehem requires 60 inches. Ask your town office or building inspector for the local figure before the foundation is designed.

Do I need an engineer to design my roof in the White Mountains?

Usually yes. The 2024 IRC's prescriptive span tables only cover allowable-stress ground snow loads of 70 psf or less, and nearly every town from Littleton north and east is above that. Truss manufacturers engineer their trusses for the load you give them, but rafters, beams, headers and timber frames need a design load set by an engineer.

What climate zone is northern New Hampshire?

New Hampshire's energy code form puts Cheshire, Hillsborough, Rockingham and Strafford counties in climate zone 5 and every other county, including Grafton and Coos, in zone 6. Zone 6 requires more wall insulation and deeper slab-edge insulation than zone 5.

How do I stop ice dams on a new house?

Keep house heat out of the attic. That means an airtight ceiling with every wire, pipe and light fixture sealed, deep insulation that runs full depth over the outside walls, no ducts or air handlers in the attic, and a continuous soffit-to-ridge vent with a 2-inch gap. Ice and water membrane at the eaves is a backup, not a cure.

Planning a build in northern New Hampshire?

Fregeau Builders has built custom homes, timber frames and additions around Littleton and the White Mountains since 1990. Tell us about your land and your plans and we'll tell you honestly what it takes.